Home
Shop
Notice: Please confirm price & availability before submitting your order due to unstable prices and shipping chain issues. TEL: +20 22 192 7338
تنبيه: يرجى التأكد من السعر وتوفر المنتج قبل إرسال الطلب نظرًا لعدم استقرار الأسعار ومشكلات الشحن. هاتف: +20 22 192 7338

+20 22 192 7338

Recently Viewed

This product is currently out of stock.

Salicru SLC-1000-TWIN PRO2, 1000 VA On-line double-conversion UPS, 699CA000003

Salicru On-line double-conversion Uninterruptible Power Systems, Advanced on-line protection for sensitive and critical loads.

Original price was: 19.751,00 EGP.Current price is: 16.144,00 EGP. 14% inc VAT

Sold by EG-tech

Availability: Out of stock
SKU:699CA000003

Salicru SLC TWIN PRO2, On-line double-conversion UPS 700 VA to 3000 VA

 

SLC TWIN PRO2: Advanced on-line protection for sensitive and critical loads

Salicru’s SLC TWIN PRO2 series is a UPS range in a tower format equipped with on-line double-conversion technology and the latest features to make it an advanced protection system for sensitive and critical loads. High output power factor (PF=0.9) to ensure availability to all types of loads.

Full control through status information via LCD display and keypad. And extensive monitoring and communication options via the built in USB HID interface, an intelligent slot for SNMP cards or relays and a wide range of software packages available – free monitoring version downloadable for Windows, Linux, Unix or Mac and packages available for multi servers or virtualized systems. For facilities that require more back-up time, there is a possibility of backup extensions using UPSs with extra charger and additional battery modules. Also notable is the possibility of Eco-mode operation to improve the efficiency of the device, EPO (emergency power off) functions, operation as a frequency converter and built-in battery test.

Salicru’s SLC TWIN PRO2 range is available in power ratings of 700, 1000, 1500, 2000 and 3000 VA.

Applications: High-performance features for single-phase environments of up to 3 kVA

Power supply failures in IT systems can cause losses as a result of downtime and the time taken to restore the system to normal operation, and damage to network hardware. Many other disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.) can also cause IT environments to malfunction.

Runtime

SLC 1000 TWIN PRO2 and SLC 1000 TWIN PRO2 B1

SLC-1000-TWIN PRO2 Runtime Graph eg-tech

Battery runtimes data: All measurements taken with new, fully charged batteries, at typical environmental conditions, and resistive load (PF = 1.0) output. These figures can differ +/- 15% around these typical values.

JM97401

Condition

New

Model

Salicru SLC-1000-TWIN PR02

Power

1000 VA / 900 W

Dimensions

35.6 x 14.4 x 22.8 cm

Weight

10.2 kg

Technical specifications
TECHNOLOGYOn-line double-conversion
FORMATTower
INPUT
Rated voltage220 / 230 / 240 V
Voltage range 100% load176 ÷ 300 V
Voltage range 40% load100 ÷ 300 V
Rated frequency50 / 60 Hz
Frequency range±10%
Total harmonic distortion (THDi)<4%
Power factor≥0.101
Auto~detection of frequencyYes
ProtectionResettable circuit breaker
OUTPUT
Power factor0.9
Rated voltage220 / 230 / 240 V
Voltage accuracy (battery mode)±1%
Power (VA/W)1000 / 900
Total harmonic distortion (THDv)<2%
Synchronised frequency±10%
Free running frequency±0.05 Hz
Frequency50 / 60 Hz
Frequency accuracy (battery mode)±0.05Hz
Compatibility with APFC loadsYes
On-line performance>89%÷92%
Eco-mode performance>98%
Admissible overloads in battery mode105% constant / 130% for 10 s / 150% for 1 s
Admissible overloads in bypass mode130% constant / 180% for 60 s
Admissible overloads in-line mode105% constant / 130% for 60 s / 150% for 10 s / >150% for 300ms
Socket typeSchuko
No. Of sockets3
BYPASS
Frequency range±5Hz
Transfer time4 ms
BATTERY
Battery typePb-Ca sealed, AGM, maintenance-free
Charge typeI/U (constant current/constant voltage)
Recharge time4 hours to 90%
Battery testManual and/or automatic programmable
COMMUNICATION
PortsUSB HID
Intelligent slotSlot for SNMP/relays
Monitoring softwareFor Windows, Linux and Mac
INDICATIONS
TypeLCD + keypad
OTHER FUNCTIONS
Cold start (start-up from batteries)Yes
Automatic restartYes
Emergency stop (EPO)Yes
OPERATING MODES
On-line double-conversionYes
Eco-modeYes
Frequency converter (CVCF)Yes (up to 60% of the load)
GENERAL
Operating temperature0º C ÷ 40º C
Relative humidityUp to 95%, non-condensing
Maxium operating altitude2,400 masl (power degradation up to 5,000 m)
Acoustic noise at 1 metre≤49 dB (100% load) / ≤41 dB (60% load)
STANDARDS
SafetyEN-IEC 62040-1
Electromagnetic compatibility (EMC)EN 62040-2
OperationVFI-SS-11 (EN-62040-3)
Corporate cerificationISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)356
Width (mm)144
Height (mm)228
WEIGHT
Weight (kg)10.2

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.