PROLINK U/UTP CAT.6A 500 MHz
Model: PL-C6A-LSZH-W
Company Commitment
We provide our customers with exceptional products in accordance with the highest international standards and offer services that meet or exceed their expectations.
Application
Suitable for Primary (Campus), Secondary (Riser), Tertiary (Horizontal) installations including outdoor environments.
- IEEE 802.3: 10Base-T, 100Base-T, 1000Base-T
- IEEE 802.5: 16 MB
- ISDN, TPDDI, ATM
- IEEE 802.3af (PoE), IEEE 802.3at (PoE+)
The cable is filled with compound to prevent water penetration, ensuring stable electrical properties even under continuous wet conditions.
Standards & Fire Rating
- ISO/IEC 11801 ed. 2.2; IEC 61156-5 2nd ed.; EN 50173-1; TIA 568-C.2
- Fire Rating: IEC 60332-1; IEC 60754-2; IEC 61034
- Water Penetration Rating: IEC 60794-1-2F5, method B
- Fire rating (PE outer sheath): IEC 60754-2; Smoke classification: No smoke emission
Description & Construction
Description: ProLink CAT 6A U/UTP Cable, 4 Pair, 23 AWG, LSZH, White, 305 m length, Reel in a box.
- Conductor: Solid copper wire AWG23 (Ø 0.58 mm)
- Insulation: Polyethylene ≤ Ø 7.0 mm
- Cable Lay Up: 4 pairs to core with non-metallic cross separator (spline)
- Cable Corralling: Waterproof compound for moisture migration prevention
- Sheath: White, LSZH
Technical Data
- Cable Designation: Industry U/UTP Cat.6 500 MHz 4P x AWG23
- Packaging: Drum 305 m
- Outer Diameter: 7.2 mm nominal
- Weight: 20 kg / km
- Thermal Load: 1884 MJ / km
- Segregation Class: b
- Tensile Force: 100 N
Mechanical Properties
- Bending Radius: ≥ 33 mm during operation (without load)
- Bending Radius: ≥ 65 mm during installation (with load)
- Temperature Range: -55°C to +60°C (operation), -15°C to +50°C (installation)
Electrical Properties (at 20°C ± 5°C)
- DC Loop Resistance: ≤ 15 Ω / 100 m
- Resistance Unbalance: ≤ 2%
- Test Voltage (core/core): 1000 V DC, 1 min
- Insulation Resistance (500 V): ≥ 4000 MΩ·km
- Capacitance: 48 pF/m nominal
- Capacitance Unbalance: ≤ 1500 pF/km
- Characteristic Impedance: 100 ± 5 Ω
- Nominal Velocity of Propagation: Approx. 67%
- Propagation Delay at 1 MHz: ≤ 535 ns / 100 m
- Delay Skew: ≤ 20 ns / 100 m
- Coupling Attenuation: ≥ 40 dB
- Balance TCL: ≤ 55 dB at 1 MHz, ≤ 40 dB at 10 MHz, ≤ 35 dB at 100 MHz
Typical Transmission Characteristics (at 20°C)
| Frequency (MHz) | Attenuation (dB/100 m) |
NEXT (dB) |
PS-NEXT (dB) |
ACR-F (dB/100 m) |
PS-ACR-F (dB/100 m) |
Return Loss (dB) |
|---|---|---|---|---|---|---|
| 4 | 3.8 | 66 | 63 | 58 | 55 | 23 |
| 10 | 6.0 | 60 | 57 | 50 | 47 | 25 |
| 20 | 8.5 | 56 | 53 | 44 | 41 | 25 |
| 62.5 | 15.5 | 48 | 45 | 34 | 31 | 21.5 |
| 100 | 19.9 | 45 | 42 | 30 | 27 | 20.1 |
| 250 | 33 | 39 | 36 | 22 | 19 | 17.3 |
| 450 | – | 44 | – | 35 | – | 20 |










Reviews