Basic Information |
Description |
S220-48P4X (48*10/100/1000BASE-T ports(380W PoE+), 4*10GE SFP+ ports, built-in AC power) |
Part Number |
98012378 |
Model |
S220-48P4X |
First supported version |
V600R023C00 |
Technical Specifications |
Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.) |
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] |
90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) |
Chassis height [U] |
1 |
Chassis material |
Metal |
Weight without packaging [kg(lb)] |
3.24 (7.14) |
Weight with packaging [kg(lb)] |
4.29 kg (9.46 lb) |
Typical power consumption [W] |
49.44 |
Typical heat dissipation [BTU/hour] |
168.69 |
Maximum power consumption [W] |
- Without PoE: 64.7 W |
- Full PoE load: 462.80 W (PoE: 380 W) |
Maximum heat dissipation [BTU/hour] |
- Without PoE: 220.76 |
- Full PoE load: 1579.12 |
Static power consumption [W] |
34.04 |
MTBF [years] |
48.14 |
MTTR [hours] |
2 |
Availability |
> 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] |
49.3 |
Noise at normal temperature (acoustic pressure) [dB(A)] |
37.3 |
Number of card slots |
0 |
Number of power slots |
0 |
Number of fans modules |
2 |
Redundant power supply |
Not supported |
Long-term operating temperature [°C(°F)] |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Devices cannot start when the temperature is lower than 0°C (32°F). |
The operating temperature ranges from –5°C (23°F) to +45°C (113°F) when optical modules with transmission distances greater than or equal to 60 km are used. |
Storage temperature [°C(°F)] |
–40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] |
0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Power supply mode |
AC built-in |
Rated input voltage [V] |
- AC input: 100 V AC to 240 V AC, 50/60 Hz |
- High-voltage DC input: 240 V DC |
Input voltage range [V] |
- AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz |
- High-voltage DC input: 190 V DC to 290 V DC |
Maximum input current [A] |
6 A |
Memory |
2 GB |
Flash memory |
Physical space: 1 GB |
Console port |
RJ45 |
Eth Management port |
Not supported |
USB |
Not supported |
RTC |
Not supported |
RPS input |
Not supported |
Service port surge protection [kV] |
Common mode: ±7 kV |
Power supply surge protection [kV] |
Differential mode: ±6 kV; common mode: ±6 kV |
Ingress protection level (dustproof/waterproof) |
IP20 |
Types of fans |
Built-in |
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction |
Air intake from left and air exhaust from right |
PoE |
Supported |
Certification |
EMC certification |
Safety certification |
Manufacturing certification |