Basic Information |
Part Number |
98012558 |
Model |
S530-48S4XE |
Description |
S530-48S4XE(48*GE SFP ports, 4*10GE SFP+ ports, 2*10GE stack ports, with 1*AC power module) |
Technical Specifications |
Remarks |
- When 25 or more GE optical modules with a transmission distance of 40 km or longer are installed on 1000BASE-X optical ports, power modules with at least 180 W power are required. |
- Copper modules can be installed on a maximum of 24 1000BASE-X optical ports. |
Chassis material |
Metal |
Height [mm] |
43.6 mm |
Depth [mm] |
420.0 mm |
Wide [mm] |
442.0 mm |
Chassis height [U] |
1 |
Weight with packaging [kg(lb)] |
7.9 (17.42) |
Weight without packaging [kg(lb)] |
6.0 (13.23) |
Maximum power consumption [W] |
- 96.40 W (with two 80 W AC power modules) |
- 104.70 W (with two 180 W AC power modules) |
- 130.05 W (with two 1200 W DC power modules) |
Typical power consumption [W] |
72.3 |
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment |
Maximum heat dissipation [BTU/hour] |
- 328.93 (with two 80 W AC power modules) |
- 357.25 (with two 180 W AC power modules) |
- 443.74 (with two 1200 W DC power modules) |
Typical heat dissipation [BTU/hour] |
246.69 |
Power supply mode |
Pluggable power supply |
Input voltage range [V] |
- AC input: 90 V AC to 290 V AC; 45–65 Hz |
- High-voltage DC input: 190 V DC to 290 V DC |
- DC input: -38.4 V DC to -72 V DC |
Rated input voltage [V] |
- AC input: 100 V AC to 240 V AC; 50/60 Hz |
- High-voltage DC input: 240 V DC |
- DC input: –48 V DC to –60 V DC |
Maximum input current [A] |
The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Number of power slots |
2 |
Number of card slots |
0 |
Memory |
2 GB |
Flash memory |
Physical space: 1 GB |
Redundant power supply |
1+1 |
Power modules without fans and power modules with fans cannot be installed in the same chassis. |
Types of fans |
Built-in |
Noise at normal temperature (acoustic power) [dB(A)] |
43.8 |
Noise at normal temperature (acoustic pressure) [dB(A)] |
31.8 |
Airflow direction |
Air intake from left, front, and right and air exhaust from rear |
Storage temperature [°C(°F)] |
–40°C to +70°C (–40°F to +158°F) |
Long-term operating temperature [°C(°F)] |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Devices cannot start when the temperature is lower than 0°C (32°F). |
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Long-term operating altitude [m(ft.)] |
0–5000 m (0–16404 ft.) |
MTBF [year] |
78.95 |
MTTR [hour] |
2 |
Availability |
> 0.99999 |
Maximum number of physical ports on the entire device |
54 |
Maximum number of 100GE ports |
0 |
Maximum number of 40GE ports |
0 |
Maximum number of 25GE ports |
0 |
Maximum number of 10GE ports |
4 |
Maximum number of GE ports |
52 |
Maximum number of FE ports |
48 |
USB |
Supported |
Console port |
RJ45 |
Eth Management port |
Supported |
Power supply surge protection |
- Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode |
- Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode |
RPS input |
Not supported |
PoE |
Not supported |
Reviews