Salicru SLC-2000-TWIN PRO2, 2000 VA On-line double-conversion UPS, 699CA000007
Salicru On-line double-conversion Uninterruptible Power Systems, Advanced on-line protection for sensitive and critical loads.
Original price was: 33.164,00 EGP.27.106,00 EGPCurrent price is: 27.106,00 EGP. 14% inc VAT
Contact us on WhatsApp Buy Now- Condition: New
- Model: Salicru SLC-2000-TWIN PR02
- Power: 2000 VA / 1800 W
- Dimensions: 39.9 x 19 x 32.7 cm
- Weight: 18.4 kg
Salicru SLC TWIN PRO2, On-line double-conversion UPS 700 VA to 3000 VA
SLC TWIN PRO2: Advanced on-line protection for sensitive and critical loads
Salicru’s SLC TWIN PRO2 series is a UPS range in a tower format equipped with on-line double-conversion technology and the latest features to make it an advanced protection system for sensitive and critical loads. High output power factor (PF=0.9) to ensure availability to all types of loads.
Full control through status information via LCD display and keypad. And extensive monitoring and communication options via the built in USB HID interface, an intelligent slot for SNMP cards or relays and a wide range of software packages available – free monitoring version downloadable for Windows, Linux, Unix or Mac and packages available for multi servers or virtualized systems. For facilities that require more back-up time, there is a possibility of backup extensions using UPSs with extra charger and additional battery modules. Also notable is the possibility of Eco-mode operation to improve the efficiency of the device, EPO (emergency power off) functions, operation as a frequency converter and built-in battery test.
Salicru’s SLC TWIN PRO2 range is available in power ratings of 700, 1000, 1500, 2000 and 3000 VA.
Applications: High-performance features for single-phase environments of up to 3 kVA
Power supply failures in IT systems can cause losses as a result of downtime and the time taken to restore the system to normal operation, and damage to network hardware. Many other disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.) can also cause IT environments to malfunction.
Condition | New |
---|---|
Model | Salicru SLC-2000-TWIN PR02 |
Power | 2000 VA / 1800 W |
Dimensions | 39.9 x 19 x 32.7 cm |
Weight | 18.4 kg |
Technical specifications | |
TECHNOLOGY | On-line double-conversion |
FORMAT | Tower |
INPUT | |
Rated voltage |
220 / 230 / 240 V
|
Voltage range 100% load |
176 ÷ 300 V
|
Voltage range 40% load |
100 ÷ 300 V
|
Rated frequency |
50 / 60 Hz
|
Frequency range |
±10%
|
Total harmonic distortion (THDi) |
<3.5%
|
Power factor |
≥0.105
|
Auto~detection of frequency | Yes |
Protection | Resettable circuit breaker |
OUTPUT | |
Power factor | 0.9 |
Rated voltage | 220 / 230 / 240 V |
Voltage accuracy (battery mode) | ±1% |
Power (VA/W) |
2000 / 1800
|
Total harmonic distortion (THDv) | <2% |
Synchronised frequency | ±10% |
Free running frequency | ±0.05 Hz |
Frequency | 50 / 60 Hz |
Frequency accuracy (battery mode) | ±0.05Hz |
Compatibility with APFC loads | Yes |
On-line performance | >89%÷92% |
Eco-mode performance | >98% |
Admissible overloads in battery mode |
105% constant / 130% for 10 s / 150% for 1 s
|
Admissible overloads in bypass mode |
130% constant / 180% for 60 s
|
Admissible overloads in-line mode |
105% constant / 130% for 60 s / 150% for 10 s / >150% for 300ms
|
Socket type | Schuko |
No. Of sockets | 4 |
BYPASS | |
Frequency range | ±5Hz |
Transfer time | 4 ms |
BATTERY | |
Battery type | Pb-Ca sealed, AGM, maintenance-free |
Charge type | I/U (constant current/constant voltage) |
Recharge time | 4 hours to 90% |
Battery test | Manual and/or automatic programmable |
COMMUNICATION | |
Ports | USB HID |
Intelligent slot | Slot for SNMP/relays |
Monitoring software | For Windows, Linux and Mac |
INDICATIONS | |
Type | LCD + keypad |
OTHER FUNCTIONS | |
Cold start (start-up from batteries) | Yes |
Automatic restart | Yes |
Emergency stop (EPO) | Yes |
OPERATING MODES | |
On-line double-conversion | Yes |
Eco-mode | Yes |
Frequency converter (CVCF) | Yes (up to 60% of the load) |
GENERAL | |
Operating temperature | 0º C ÷ 40º C |
Relative humidity | Up to 95%, non-condensing |
Maxium operating altitude | 2,400 masl (power degradation up to 5,000 m) |
Acoustic noise at 1 metre | ≤49 dB (100% load) / ≤41 dB (60% load) |
STANDARDS | |
Safety | EN-IEC 62040-1 |
Electromagnetic compatibility (EMC) | EN 62040-2 |
Operation | VFI-SS-11 (EN-62040-3) |
Corporate cerification | ISO 9001, ISO 14001, ISO 45001 |
DIMENSIONS | |
Depth (mm) | 399 |
Width (mm) | 190 |
Height (mm) | 327 |
WEIGHT | |
Weight (kg) | 18.4 |